PRIOn Logo

CVE-2024-33494 Design/Logic Flaw

Routine
Remediate Within 6 Months

CVE Information

Original CVE data

Published:
Updated:

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing.

CWE: CWE-345
CVSS v2-
CVSS v3-
References
https://cert-portal.siemens.com/productcert/html/ssa-093430.html
Affected Vendors

Basic Analysis

Common vulnerability metrics

Vulnerabilty type as detected by PRIOnengine

Design/Logic Flaw

CVSS Scores as calculated by PRIOnengine
CVSS v24.3
AV:N/AC:M/AU:N/C:N/I:N/A:P
CVSS v38.1
AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
MITRE CWE Top 25

-

Exploits

No exploit code is reported to exist.

Active Exploitation

Vulnerability is not in CISA's Known Exploited Vulnerabilities (KEV) catalog. See the KEV Catalog

Social Network Activity

-

Threat Actor Activity

No sightings of the vulnerability within threat reports.

Cybersecurity Frameworks

How the vulnerability maps against various cybersecurity frameworks

-

Compliance Impact

How the submited vulnerability affects compliance

-

Web Application Security Frameworks

Applicable if the issue likely affects a web application

-