PRIOn Logo

CVE-2023-7017 Design/Logic Flaw

Routine
Remediate Within 6 Months

CVE Information

Original CVE data

Published:
Updated:

Sciener locks' firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device.

CWE:
CVSS v2-
CVSS v3-
References
https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/
Affected Vendors

Basic Analysis

Common vulnerability metrics

Vulnerabilty type as detected by PRIOnengine

Design/Logic Flaw

CVSS Scores as calculated by PRIOnengine
CVSS v28.3
AV:A/AC:L/AU:N/C:C/I:C/A:C
CVSS v38.8
AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
MITRE CWE Top 25

-

Exploits

No exploit code is reported to exist.

Active Exploitation

Vulnerability is not in CISA's Known Exploited Vulnerabilities (KEV) catalog. See the KEV Catalog

Social Network Activity

-

Threat Actor Activity

No sightings of the vulnerability within threat reports.

Cybersecurity Frameworks

How the vulnerability maps against various cybersecurity frameworks

-

Compliance Impact

How the submited vulnerability affects compliance

-

Web Application Security Frameworks

Applicable if the issue likely affects a web application

-