PRIOn Logo

CVE-2022-32251 Authentication flaw

Significant
Remediate Within one Month

CVE Information

Original CVE data

Published:
Updated:

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.

CWE: CWE-306
CVSS v27.5
AV:N/AC:L/AU:N/C:P/I:P/A:P
CVSS v39.8
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
References
https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf
https://cert-portal.siemens.com/productcert/html/ssa-484086.html
Affected Vendors

Siemens - (1)

Basic Analysis

Common vulnerability metrics

Vulnerabilty type as detected by PRIOnengine

Authentication flaw

CVSS Scores as calculated by PRIOnengine
CVSS v26.5
AV:N/AC:L/AU:S/C:P/I:P/A:P
CVSS v38.8
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
MITRE CWE Top 25

Vulnerability weakness type is in the top 25 CWEs according to MITRE. View Mitre Top 25 CWEs

Exploits

No exploit code is reported to exist.

Active Exploitation

Vulnerability is not in CISA's Known Exploited Vulnerabilities (KEV) catalog. See the KEV Catalog

Social Network Activity

-

Threat Actor Activity

No sightings of the vulnerability within threat reports.

Cybersecurity Frameworks

How the vulnerability maps against various cybersecurity frameworks

-

Compliance Impact

How the submited vulnerability affects compliance

PCI DSS v3.2.1-6.5.10 - Broken Authentication & Session Management

Web Application Security Frameworks

Applicable if the issue likely affects a web application

WASC-19 - SQL Injection